The SMC HRS400-A-46 chiller stands as a leading solution for demanding cooling applications. This article delves into the specifications, benefits, applications, and essential considerations for utilizing this exceptional chiller.
Cooling Capacity: 400,000 BTU/hr
Power Input: 460V, 3-phase, 60Hz
Refrigerant: R-410A
Scroll Compressors: 2
Condenser: Air-cooled
Evaporator: Plate-and-frame
Dimensions: 120" L x 48" W x 72" H
Weight: 2,800 lbs
The SMC HRS400-A-46 chiller is ideal for a wide range of applications, including:
1. Determine Cooling Load: Calculate the cooling requirement of the application using industry-standard methods.
2. Select Chiller: Choose a chiller with a cooling capacity that closely matches the calculated cooling load.
3. Install Chiller: Follow manufacturer's instructions for proper installation, including electrical wiring, piping, and refrigerant charging.
4. Commission Chiller: Start and test the chiller system to ensure all components are operating correctly.
5. Monitor Performance: Track chiller performance and adjust settings as needed to optimize energy efficiency and maintain target temperatures.
Pros:
Cons:
1. What refrigerant does the SMC HRS400-A-46 chiller use?
R-410A
2. What is the SEER rating of the SMC HRS400-A-46 chiller?
16
3. What is the sound level of the SMC HRS400-A-46 chiller?
65 dB(A)
4. What is the warranty period for the SMC HRS400-A-46 chiller?
5 years (parts and labor)
5. Is the SMC HRS400-A-46 chiller Energy Star-certified?
Yes
6. What is the average lifespan of the SMC HRS400-A-46 chiller?
15-20 years with proper maintenance
Table 1: SMC HRS400-A-46 Chiller Specifications
Feature | Value |
---|---|
Cooling Capacity | 400,000 BTU/hr |
Power Input | 460V, 3-phase, 60Hz |
Refrigerant | R-410A |
Scroll Compressors | 2 |
Condenser | Air-cooled |
Evaporator | Plate-and-frame |
Dimensions | 120" L x 48" W x 72" H |
Weight | 2,800 lbs |
Table 2: SMC HRS400-A-46 Chiller Benefits
Benefit | Description |
---|---|
High Energy Efficiency | Energy Star-certified, SEER rating of 16 |
Precise Temperature Control | PID microprocessor controller, ±0.5°F setpoint accuracy |
Low Operating Costs | Advanced scroll compressors reduce energy consumption |
Durable Construction | Galvanized steel cabinet, corrosion-resistant components |
Quiet Operation | Sound level of 65 dB(A) |
Environmentally Friendly | R-410A refrigerant, zero ODP |
Table 3: Common Mistakes to Avoid with the SMC HRS400-A-46 Chiller
Mistake | Consequences |
---|---|
Oversizing the Chiller | Inefficiencies, increased operating costs |
Improper Installation | Compromised performance, potential chiller damage |
Lack of Maintenance | Unexpected failures, reduced chiller lifespan |
2024-10-02 09:01:08 UTC
2024-10-02 09:03:48 UTC
2024-10-02 08:47:21 UTC
2024-10-02 08:54:03 UTC
2024-10-02 09:10:35 UTC
2024-10-02 10:41:50 UTC
2024-10-02 09:16:31 UTC
2024-10-02 08:44:42 UTC
2024-10-02 09:07:15 UTC
2024-10-02 08:56:49 UTC
2024-10-08 22:35:26 UTC
2024-10-08 07:44:28 UTC
2024-10-04 09:41:44 UTC
2024-10-14 00:42:53 UTC
2024-10-08 17:35:22 UTC
2024-10-14 22:34:43 UTC
2024-10-16 09:08:41 UTC
2024-10-16 09:08:13 UTC
2024-10-16 09:08:06 UTC
2024-10-16 09:07:50 UTC
2024-10-16 09:07:40 UTC
2024-10-16 09:07:15 UTC
2024-10-16 09:07:06 UTC